Service Details:
Tube Voltage | 220v |
AERB Approved | Yes |
Operation Mode | Automatic |
Technology Type | Digital |
Dimensions | 46x46x1.5 cm |
I Deal In | New Only |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationBrand | All |
Model Name/Number | DR Type 2 |
Frequency | 50-60 Hz |
Dimensions | 46x46x1.5 cm |
Spatial Resolution | 3.6LP/ mm |
Detector Technology | a-Si |
Scintillator | GOS/CSI |
Image Size | 43x43 cm (17x17 inch ) |
Pixel Matrix | 3072x3072 Pixel |
Pixel Pitch | 140mu m |
Minimum Detectable Dose | 20 nGy( GOS) |
Maximum Linear Dose | 150mu gy (GOS) (RQA5)) |
Ghost | <0.25% (300 mu Gy,60s) |
Image Acquisition Time | 1 s( Wired) |
X-Ray Voltage Range | 40-150 KV |
Battery Standby Time | 8 H |
Data Interface | GigE/802.11 ac |
Voltage | AC 100-240 V |
Weight | 4.3 kg (Wired) |
Housing Material | Carbon, Alloy |
Water Tightness | IPX3 |
Operating Environment Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only |
5-35 Degree Celsius,10-75% RH |
List number |
r |
disclaimer |
unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appears with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturere. |
Additional Information:
Service Details:
Exposure Time | 2Sec |
Operation Mode | Automatic |
Peak Kilo Voltage | 100 kvP |
Usage/Application | Dental |
I Deal In | New and Second Hand |
Technology Type | Digital |
List No. | r |
Product DescriptionHigh frequency DC constant voltage control technology
List number | r |
Disclaimer | unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Exposure Time | 2Sec |
Operation Mode | Automatic |
Peak Kilo Voltage | 100 kvP |
Usage/Application | Dental |
I Deal In | New and Second Hand |
Technology Type | Digital |
List No. | r |
Technical specifications :
| Technical Data |
Generator | Constant potential, microprocessor-controlled |
Working frequency | 145 - 230 KHz with self-adjustment (typically 175 KHz) |
Focal spot | 0.4 mm (IEC 336) |
Total filtration | 2.0 mm Al @ 70 kV |
Anode current | 4 / 8 mA |
Voltage at X-ray tube | 60 / 65 / 70 kV (*) |
Exposure times | 0.020 – 1.000 seconds, R’10 and R’20 scale |
Source-skin distance | 20 and 30 cm |
Irradiated field | Ø 55 mm and Ø 60 mm round |
Additional collimators | 35 x 45 mm rectangular, 31 x 41 mm and 22 x 35 mm, for sensors size 2 and size 1 |
Power supply | 50/60 Hz, 115-120 V AC ±10% or 230-240 V AC ±10% |
Duty Cycle | Continuous operation with self-adjustment up to 1s/80s total |
Arms (for Standard version only) | Available in 3 lengths: 40 cm – 60 cm – 90 cm |
Max. arm extension | 230 cm, from wall |
Certification | CE 0051, FDA approved |
Versions | Standard (wall mounted) or Mobile (on portable cart) |
List number | r |
Disclaimer | unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Brand | Starnuke |
Generator Capacity | 100 mA |
Generator Type | High Frequency |
Power Supply Volts | 220 V |
Power Supply Frequency | 50 Hz |
Operation Mode | Automatic |
Peak Kilo Voltage | 100 kvP |
List No. | r |
Brand | Star Nuke |
Model Name/Number | Ardent-70 |
Generator Capacity | 10 mA |
Exposure Time | 0.1 Sec to 3.0 Sec. |
Generator Ma | 10 |
Generator Power | 70 KV |
Focal Spot | 0.8 mm X 0.8 mm |
Machine Type | Wall Mounted |
Generator Type | Line Frequency |
Power Supply Frequency | 50 Hz |
AERB Approved | Yes |
Generator | 230V +- 10% 50 Hz,5 Amp |
Generator KVp | 70 |
Country of Origin | Made in India |
Minimum Order Quantity | 1 |
Dental-IOP X-Ray Machine
ARDENT-70
We Star Nuke offer AERB Approved Dental IOP X Ray Machine (Model-Ardent 70). This product is manufactured using only quality tested materials.
Warranty: 2 Years on electrical parts 2 year warranty on electrical parts which Digital timer / processor, Remote control and High voltage transformer and 1 year guaranty of x ray tube.
We have strict quality control process in which product are tested to have high quality image profile as well to ensure durability and consistent performance. Therefore, we provide Unmatched Warranty in Dental X ray machine in India.
Features -
• Microprocessor based X-ray timer.
• Independent memory for Digital and Conventional / scissor Dental Radiography time selections.
• Short time exposure range starting from 0.02 sec. makes it ideal for Digital Radiography.
• Soft touch panel switches.
• Line voltage compensation 170 - 260 V in 12 uniform steps.
• Tube overload protection for longer tube life.
• 10 seconds time delay between two consecutive exposures.
• Audio-visual indications during exposure and in tube overload condition.
• LED indicators to indicate ready sign and Digital Radiography (RVG) selection.
• Lead coated, irremovable, long radiography cone.
• Side mounting of tube head provides high maneuverability and quick positioning.
List number | r |
Disclaimer | unless otherwise indicated the content of this “website” is the proprietary property of its owners. however, trademarks, service marks and/or logos [called “marks”] herein associated with the products listed on this” website” are the property of their respective owners and if they appear with the listed products, it is only used for the purpose of identification of those products. we do not claim as association with the mark owners, unless otherwise so specified. meaning of list number: - “r” means refurbished, “po” means preowned, “u” means used, “t” means trading, “m” means own manufactured, “ad” means authorised dealer of original equipment manufacturer. |
Additional Information:
Service Details:
Exposure Time | All |
Operation Mode | Semi Automatic |
Peak Kilo Voltage | 100 kvP |
Usage/Application | Radiography |
I Deal In | New and Second Hand |
Technology Type | Digital |
List No. | r |
Note:- Please Do Not Refer Above Mentioned Prices Please Contact Us To Know The Prices.
Product SpecificationModel Name/Number | Ray 68 AC |
Exposure Time | 0.06 to 2.0 second |
Focal Spot | 0.8 mm |
Is It Portable | Floor Mounted |
Focal Length | 20 cm |
Intellectual property: Trademark, copyright or any other type of intellectual property rights are property of their respective owner. Inorbvict is trader, resaler , refurbisher only
List number | r |
Disclaimer | UNLESS OTHERWISE INDICATED THE CONTENT OF THIS “WEBSITE” IS THE PROPRIETARY PROPERTY OF ITS OWNERS. HOWEVER, TRADEMARKS, SERVICE MARKS AND/OR LOGOS [CALLED “MARKS”] HEREIN ASSOCIATED WITH THE PRODUCTS LISTED ON THIS” WEBSITE” ARE THE PROPERTY OF THEIR RESPECTIVE OWNERS AND IF THEY APPEARS WITH THE LISTED PRODUCTS, IT IS ONLY USED FOR THE PURPOSE OF IDENTIFICATION OF THOSE PRODUCTS. WE DO NOT CLAIM AS ASSOCIATION WITH THE MARK OWNERS, UNLESS OTHERWISE SO SPECIFIED. MEANING OF LIST NUMBER: - “R” MEANS REFURBISHED, “PO” MEANS PREOWNED, “U” MEANS USED, “T” MEANS TRADING, “M” MEANS OWN MANUFACTURED, “AD” MEANS AUTHORISED DEALER OF ORIGINAL EQUIPMENT MANUFACTURERE. |
Additional Information: